Dosimeter Response for Personal Eye Lens Using TLD-900 (CaSO4:Dy) in Radiation Field Beta and Photon
نویسندگان
چکیده
منابع مشابه
Evaluation of Occupational Radiation Status and Validity of Individual Dose and Eye Lens Assessment Using Single Film Dosimeter for Angiographic Staff in Iran
Background and Aim: In angiography, the lens of the eye may be exposed to radiation and cause cataracts. In Iran, at present, only a single film dosimeter is used under the lead-apron to evaluate individual doses. The aim of this study was to investigate the status of occupational radiation as well as the validity of measuring the dose of the whole body of individuals and eye lenses using a sin...
متن کاملAchievement of Quality Control Parameters for NIS Personal Thermoluminescence Dosimeter (TLD) System
This work intend to identify and follow up quality control parameters to improve thermoluminescence dosemeter (TLD) system used for personal dosimetry in ionizing radiation metrology laboratory (IRML). Characterization of personal dosimetry system has presented in terms of the stability of reader calibration factors, linearity of response for Cs as reference radiation source, energy and angular...
متن کاملMeasurement of the Adsorbed Radiation Dose to Eyelens During CT Scan and Radiotherapy of Nasopharynx Cancer
Introduction: The study of the cause of death during the last few decades has shown that death due to infectious diseases has been declining and has been rising due to noninvasive diseases, especially cancers and accidents. Cancer is considered as one of the fatal diseases, and every year, more than 10.9 million people worldwide are diagnosed with the disease. Mater...
متن کاملResponse of TLD and RPL personal dosimeters in a national inter-comparison test program
Background: Different kinds and models of personal dosimeters are used in individual monitoring by workers. Performance testing as part of approval procedures is carried out to demonstrate that the essential performance specifications are routinely maintained. There are four service providers in Iran which use different luminescence techniques (i. e. TLD and RPL) with various kinds of dos...
متن کاملEvaluation of radiation absorption by thyroid gland and eye lens in trophy panoramic radiography
Evaluation of radiation absorption by thyroid gland and eye lens in trophy panoramic radiography Dr.AR. Talaee Pour *- Dr. S. Sahba ** - Dr. M. Maleknia***. *- Associate professor of Oral & Maxillofacial radiology Dept.- Faculty of Dentistry - Tehran University of Medical Sciences. ** - Associate professor of Oral Diseases and Diagnosis.- Faculty of Dentistry - Shaheed Beheshti University of Me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Natural-B
سال: 2016
ISSN: 2088-4613,2301-4202
DOI: 10.21776/ub.natural-b.2016.003.03.06