Dose Reduction in Automatic Optimization Parameter of Full Field Digital Mammography: Breast Phantom Study
نویسندگان
چکیده
منابع مشابه
Dose Reduction in Automatic Optimization Parameter of Full Field Digital Mammography: Breast Phantom Study
PURPOSE We evaluated the impact of three automatic optimization of parameters (AOP) modes of digital mammography on the dose and image quality. METHODS Computerized Imaging Reference Systems phantoms were used. A total of 12 phantoms with different thickness and glandularity were imaged. We analyzed the average glandular dose (AGD) and entrance surface exposure (ESE) of 12 phantoms imaged by ...
متن کاملFull Field Digital Mammography with Breast Cushions in Screening Subjects
To explore the impact of radiolucent breast cushions on breast pain and image quality of full field digital mammography (FFDM) in screening subjects. The American College of Radiology (ACR) phantom and fifty-four women were enrolled in this study. Use of cushions reduced pain (p < 0.001). The imaging quality with cushions was inferior to those without cushions in phantom studies (p ≦ 0.01), on ...
متن کاملWhich Phantom Is Better for Assessing the Image Quality in Full-Field Digital Mammography?: American College of Radiology Accreditation Phantom versus Digital Mammography Accreditation Phantom
OBJECTIVE To compare between the American College of Radiology (ACR) accreditation phantom and digital mammography accreditation phantom in assessing the image quality in full-field digital mammography (FFDM). MATERIALS AND METHODS In each week throughout the 42-week study, we obtained phantom images using both the ACR accreditation phantom and the digital mammography accreditation phantom, a...
متن کاملDigital breast tomosynthesis (DBT) versus full field digital mammography (FFDM): comparison of a system performance using a contrast detail phantom
To evaluate performance (image signal to noise ratio) of a digital mammographic system working in 2D planar versus tomosynthesis modality, a contrast detail phantom was developed embedding 1 cm plexyglas, including 49 holes of different diameter and depth, between two layers containing a breast simulating material. The acquisition protocol included 15 low dose projections (reconstructed 1mm-thi...
متن کاملClinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer.
OBJECTIVE The purpose of this work is to compare full-field digital mammography and screen-film mammography for the detection of breast cancer in a screening population. SUBJECTS AND METHODS Full-field digital mammography was performed in addition to screen-film mammography in 6736 examinations of women 40 years old and older presenting for screening mammography at either of two institutions....