Dose rate-dependent marrow toxicity of TBI in dogs and marrow sparing effect at high dose rate by dose fractionation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

Syngeneic and allogeneic bone marrow engraftment after total body irradiation: dependence on dose, dose rate, and fractionation.

Murine bone marrow chimera models were used to assess the efficacy of host total body irradiation (TBI) given at different doses, dose rates, and fractionation schemes in providing for engraftment of syngeneic and allogeneic bone marrow. B6-Hbbd congenic and LP mice, respectively, were used as donors (10(7) bone marrow cells) for syngeneic and allogenic (H-2 compatible) transplantation in stand...

متن کامل

Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

Quality assurance prusedore in high dose rate bracythrapy

Introduction: Quality assurance is essential for obtaining the best achievable tumor control, avoiding unnecessary side effects, accuracy and safety during performing High Dose Rate (HDR) Brachytherapy (BT). Quality assurance is extremely important because HDR BT procedures are performed quickly, with high doses given in a short time period, with little opportunity for correcti...

متن کامل

Effect of dose-rate and lung dose in total body irradiation on interstitial pneumonitis after bone marrow transplantation.

The aim of this study is to evaluate the incidence of interstitial pneumonitis following fractionated total body irradiation conditioning for bone marrow transplantation with varying lung doses due to shielding technique and different dose-rates. Between 1987 and 2001, a total number of 105 patients have received total body irradiation conditioning for bone marrow transplantation for hematologi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Biology of Blood and Marrow Transplantation

سال: 1999

ISSN: 1083-8791

DOI: 10.1053/bbmt.1999.v5.pm10392961