Dose Quantities Used in Radiological Protection for Internal Radiation Exposure
نویسندگان
چکیده
منابع مشابه
Evaluation of Gonadal Exposure Dose in Long Bone Plain Radiography for Radiation Protection
Introduction: Long bone examination in standing position, as one of the diagnostic methods in plain radiography, is most commonly used in the field of medical diagnosis, especially leg length discrepancy. However, with regard to this examination, reproductive organs are exposed to radiation as they are placed in the adjacent area to the long bone. Due to the sensitivit...
متن کامل21/110/05 DRAFT FOR DISCUSSION INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION COMMITTEE 2 BASIS FOR DOSIMETRIC QUANTITIES USED IN RADIOLOGICAL PROTECTION Task Group of ICRP Committee 2:
متن کامل
Dose and dose-rate effects of ionizing radiation: a discussion in the light of radiological protection.
The biological effects on humans of low-dose and low-dose-rate exposures to ionizing radiation have always been of major interest. The most recent concept as suggested by the International Commission on Radiological Protection (ICRP) is to extrapolate existing epidemiological data at high doses and dose rates down to low doses and low dose rates relevant to radiological protection, using the so...
متن کاملAre Radiation Exposure Levels Used in Cardiology Dangerous?
Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...
متن کاملApplication of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology
Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 2013
ISSN: 0033-8303,1884-4111
DOI: 10.3769/radioisotopes.62.465