Dose Distribution from kV-Cone Beam Computed Tomography in Image-guided Radiotherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Variation in Dose Calculation Accuracy Between kV Cone-Beam Computed Tomography and kV fan-Beam Computed Tomography

Cone-beam computed tomography (CBCT) images are presently used for geometric verification for daily patient positioning. In this work, we have compared the images of CBCT with the images of conventional fan beam CT (FBCT) in terms of image quality and Hounsfield units (HUs). We also compared the dose calculated using CBCT with that of FBCT. Homogenous RW3 plates and Catphan phantom were scanned...

متن کامل

Cone beam computed tomography radiation dose and image quality assessments.

Diagnostic radiology has undergone profound changes in the last 30 years. New technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and reconstruction, image ...

متن کامل

Commissioning of Kilo-voltage Cone Beam Computed Tomography for Image-guided Radiotherapy

kV-CBCT integrated with linear accelerators as a tool for IGRT, was developed to acquire online volumetric and anatomical images (Xing 2006). The successful implementation of CBCT requires a quality assurance (QA) program that not only involves robust and intuitive quality control checks of the equipment, but also thoughtful image-guidance processes based on measurement of positional uncertaint...

متن کامل

Rationale and Technology of Cone-beam Computed Tomography-based Image-guided Radiotherapy

Cone-beam Computed Tomography-based Image-guided Radiotherapy Variation of the target position is a major challenge in the clinical practice of external beam radiotherapy (EBRT). Variability of the tumour position from day to day is caused by breathing, changes of the filling of hollow organs and peristaltic or more complex changes of the anatomy of patients. If not corrected or compensated for...

متن کامل

Imaging dose from cone beam computed tomography in radiation therapy.

Imaging dose in radiation therapy has traditionally been ignored due to its low magnitude and frequency in comparison to therapeutic dose used to treat patients. The advent of modern, volumetric, imaging modalities, often as an integral part of linear accelerators, has facilitated the implementation of image-guided radiation therapy (IGRT), which is often accomplished by daily imaging of patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 2013

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.2013_jsrt_69.7.753