Dose Buildup Factor Measurements with a Long Ionization Chamber
نویسندگان
چکیده
منابع مشابه
Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملEvaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731
Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...
متن کاملNIST Ionization Chamber “A” Sample-Height Corrections
For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber "A" (PIC "A") to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source positioning ring over time. The temporal change in the holder caused an error in the source-heig...
متن کاملcalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
background: the effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted standards. secondary standard dosimetry laboratory (ssdl) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192ir . this work has been carried out to calibrate the high dose rat...
متن کاملInstability Dynamics with Electron Cloud Buildup in Long Bunches
LONG BUNCHES M. Blaskiewicz , BNL 911B, Upton, NY 11973-5000, USA Abstract For long bunches, trailing edge multi-pacting causes the electron cloud density at the trailing edge of the bunch to be significantly larger than the cloud density during the early and central portions of the bunch. The effective wakefield is modeled and compared with hand estimates. Instabilty simulations, which include...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan
سال: 1966
ISSN: 0004-7120
DOI: 10.3327/jaesj.8.424