Dominant frequency content of ocular microtremor from normal subjects

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dominant frequency content of ocular microtremor from normal subjects

Ocular microtremor (OMT) is a high frequency tremor of the eyes present during fixation and probably related to brainstem activity (Coakley, D. (1983). Minute eye movement and brain stem function. CRC Press, FL.). Published observations on the frequency of OMT have varied widely. Ocular microtremor was recorded in 105 normal healthy subjects using the Piezoelectric strain gauge technique. The d...

متن کامل

Effect of age on ocular microtremor activity.

BACKGROUND Ocular microtremor (OMT) is a high-frequency tremor of the eyes. It is present in all individuals and is related to brainstem activity. The OMT signal appears as an irregular oscillatory movement with intermittent burst-like components. The clinical interest in OMT has centered on its use in the assessment of the comatose patient, with broad agreement among authors of its prognostic ...

متن کامل

Ocular microtremor measurement using laser-speckle metrology.

We describe a novel, noninvasive measurement approach for recording a small involuntary tremor of the eye known as ocular microtremor. The method is based on measuring out-of-plane angular displacements of a target by using laser-speckle correlation of images recorded in the Fourier plane of a lens. The system has a dynamic range of 4 to 5000 μrad, resolution of 4 μrad, and a bandwidth of 250 H...

متن کامل

Speckle interferometric sensor to measure low-amplitude high frequency Ocular Microtremor (OMT)

Ocular microtremor (OMT) is a physiological high frequency (up to 150Hz) low amplitude (150-2500nm) involuntary tremor of the human eye. It is one of the three fixational ocular motions described by Adler and Fliegelman in 1934 as well as microsaccades and drift. Clinical OMT investigations to date have used eye-contacting piezoelectric probes or piezoelectric strain gauges. Before contact can ...

متن کامل

Ocular microtremor: a tool for measuring depth of anaesthesia?

Ocular microtremor (OMT) is a fine high frequency tremor of the eyes caused by extra-ocular muscle activity stimulated by impulses emanating in the brain stem. Several studies have shown that the frequency of this tremor is reduced in patients whose consciousness is reduced by anaesthesia or head injury. Therefore, OMT may possibly be used to determine depth of anaesthesia. Twenty-two unpre-med...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Vision Research

سال: 1999

ISSN: 0042-6989

DOI: 10.1016/s0042-6989(98)00322-8