Does chlorhexidine in different formulations interfere with the force of orthodontic elastics?

OBJECTIVE To evaluate the effects of different concentrations of chlorhexidine on the decline in force of orthodontic elastics. MATERIALS AND METHODS In a laboratory study, five groups of samples were tested, with one control group represented by distilled water (group 1) and four experimental groups: 0.12% manipulated chlorhexidine (group 2), 0.2% manipulated chlorhexidine (group 3), 0.12% c...

متن کامل

Force Relaxation Characteristics of Medium Force Orthodontic Latex Elastics: A Pilot Study

To evaluate force extension relaxation of different brands and diameters of latex elastics subjected to static tensile testing under an apparatus designed to simulate oral environments, sample sizes of 5 elastics from American Orthodontics (AO), Tp, and Morelli Orthodontics (Mo) of equivalent medium force, (3/16, 1/4, and 5/16 inch size) were tested. The forces were read after 1-, 3-, 6-, 12- a...

متن کامل

the effect of task cognitive complexity and time limit on the performance of the learners with different proficiency levels in second language writing skill

this study investigated the effects of manipulating the cognitive complexity of tasks along +/- few elements and the time limits on l2 learners writing performance. to conduct the study, 60 iranian efl learners with two levels of proficiency, low and high intermediate, were selected and assigned to three groups based on the time devoted to task completion. the participants performed both a simp...

15 صفحه اول

In vitro study of force decay of latex and non-latex orthodontic elastics.

The aim of this study was to evaluate the force decay of two brands of orthodontic elastics, both offering latex and non-latex products. Samples were subjected to continuous stretching, measuring force at 5 seconds, 8 hours, and 24 hours in both dry and wet conditions. Five hundred samples were used, GAC® and Lancer® 0.25 inch and 4 oz, divided into testing sample sizes of n = 25 per group. For...

متن کامل

An In-vitro Comparison of Force Loss of Orthodontic Non-Latex Elastics

OBJECTIVE The amount and consistency of the applied forces to the tooth are important factors in tooth movements; therefore, the aim of this study was to compare the initial force and the force loss of three brands of elastics in 24 hours. MATERIALS AND METHODS In this in-vitro study sixty non-latex elastics (3/16 medium) from three companies (Forestadent, Dentaurum and Ortho Technology) were...