Does b1000–b0 Mismatch Challenge Diffusion-Weighted Imaging–Fluid Attenuated Inversion Recovery Mismatch in Stroke?

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does b1000-b0 Mismatch Challenge Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery Mismatch in Stroke?

BACKGROUND AND PURPOSE Our aim was to explore whether the mismatch in lesion visibility between b1000 and b0 images is an alternative to mismatch between diffusion-weighted imaging and fluid-attenuated inversion recovery imaging as a surrogate marker of stroke age. METHODS We analyzed patients from the European multicenter I-KNOW database. Independent readers assessed the visibility of ischem...

متن کامل

Diffusion-weighted image and fluid-attenuated inversion recovery image mismatch: unclear-onset versus clear-onset stroke.

BACKGROUND AND PURPOSE Mismatch in lesion visibility between diffusion-weighted image and fluid-attenuated inversion recovery image (DWI-FLAIR mismatch) has been proposed as a biomarker for the estimation of ischemic lesion age. The actual onset in some patients with unclear-onset stroke (UnCOS) may be close to the first-found abnormal time. We hypothesized that patients with UnCOS within a par...

متن کامل

Prediction of Stroke Onset Is Improved by Relative Fluid-Attenuated Inversion Recovery and Perfusion Imaging Compared to the Visual Diffusion-Weighted Imaging/Fluid-Attenuated Inversion Recovery Mismatch.

BACKGROUND AND PURPOSE Acute stroke patients with unknown time of symptom onset are ineligible for thrombolysis. The diffusion-weighted imaging and fluid-attenuated inversion recovery (FLAIR) mismatch is a reasonable predictor of stroke within 4.5 hours of symptom onset, and its clinical usefulness in selecting patients for thrombolysis is currently being investigated. The accuracy of the visua...

متن کامل

Fluid-Attenuated Inversion Recovery Vascular Hyperintensities-Diffusion-Weighted Imaging Mismatch Identifies Acute Stroke Patients Most Likely to Benefit From Recanalization.

BACKGROUND AND PURPOSE Fluid-attenuated inversion recovery vascular hyperintensities (FVH) beyond the boundaries of diffusion-weighted imaging (DWI) lesion (FVH-DWI mismatch) have been proposed as an alternative to perfusion-weighted imaging (PWI)-DWI mismatch. We aimed to establish whether FVH-DWI mismatch can identify patients most likely to benefit from recanalization. METHODS FVH-DWI mism...

متن کامل

Diffusion-weighted imaging–fluid-attenuated inversion recovery mismatch is associated with better neurologic response to intravenous thrombolytic therapy in acute ischemic stroke patients

OBJECTIVE To investigate differences in the effect of intravenous (IV) thrombolysis regarding the mismatch of diffusion-weighted imaging-fluid-attenuated inversion recovery (DWI-FLAIR) among acute ischemic stroke patients who visited the emergency department (ED) within 3 hours from the onset of symptoms. METHODS Among ED patients presenting with an acute ischemic stroke between January 2011 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Stroke

سال: 2016

ISSN: 0039-2499,1524-4628

DOI: 10.1161/strokeaha.115.011501