DLTS spectra of radiation-induced defects in silicon detectors with heavily damaged Bragg peak region

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Radiation Damaged P-in-n and N-in-n Silicon Microstrip Detectors

Two p-in-n and one n-in-n silicon microstrip detectors were radiation-damaged and tested in a beam. A comparison was made between the p-in-n and the n-in-n in high resistivity wafers, and the p-in-n in a low and a high resistivity wafer. The charge collection showed a clear difference in the n-in-n and the p-in-n detectors, which suggested that the signals were shared between strips more in the...

متن کامل

Cryogenic temperature performance of heavily irradiated silicon detectors

The charge collection e$ciency (CCE) of silicon detectors, previously irradiated with high neutron #uences, has been measured at 4.2, 77 and 195 K. The CCE recovery measured after 1.2]1014 n/cm2 is 100% at a bias voltage of 50 V. For 2]1015 n/cm2 the most probable signal collected for minimum ionising particles is 13 000 electrons, corresponding to 50% CCE, at a bias voltage of 250 V. Negligibl...

متن کامل

Does Radiation Improve Silicon Detectors?

Sensors designed for the CMS Preshower detector were irradiated with protons and neutrons to fluences equivalent up to 2x10 n/cm. The leakage current and the capacitance as well as the charge collection efficiency and the noise were measured, before and after the irradiation, for most of the detectors. We noticed, that for some detectors of a lower quality, the breakdown voltage increases after...

متن کامل

Optimization of the priming procedure for Thermally Stimulated Currents with heavily irradiated silicon detectors

We report on the investigation of the radiation damage induced by neutron irradiation on both nand p-type Magnetic Czochralski silicon pad detectors by the Thermally Stimulated Currents (TSC) technique. Detectors have been irradiated with fast neutrons in the range 10 14 -10 16 n/cm 2 . Priming conditions have been studied in detail in order to investigate the residual electric field due to fro...

متن کامل

Relationship between Strained Silicon-oxygen Bonds and Radiation Induced Paramagnetic Point Defects in Silicon Dioxide

We have investigated the radiation induced generation of paramagnetic point defects in high surface area sol-gel silicates containing various concentrations of the Raman active 608 cm -~ D 2 band attributed to strained cyclic trisiloxanes (3-membered rings). Our results suggest a correlation between the concentration of the 3-membered rings with the concentration of radiation induced paramagnet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2020

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/1697/1/012071