Diurnal Variation of Anterior Chamber Flare
نویسندگان
چکیده
منابع مشابه
Anterior chamber flare after femtosecond laser-assisted cataract surgery.
PURPOSE To determine whether postoperative ocular inflammation is less after femtosecond laser-assisted cataract surgery than after conventional phacoemulsification (manual) cataract surgery. SETTING Private clinic, Launceston, Tasmania, Australia. DESIGN Prospective consecutive investigator-masked nonrandomized parallel cohort study. METHODS Consecutive cataract patients who had femtosec...
متن کاملAnterior chamber flare after trabeculectomy and after phacoemulsification.
AIMS To evaluate and compare prospectively the anterior chamber inflammatory response after phacoemulsification cataract surgery and after trabeculectomy with peripheral iridectomy. METHODS Anterior chamber inflammation was measured using the Kowa FM-500 laser flare meter in 131 patients undergoing trabeculectomy and 148 patients undergoing phacoemulsification cataract extraction with intraoc...
متن کاملChanges in anterior chamber flare and cells following cataract surgery.
The laser flare cell meter allows rapid non-invasive quantification of aqueous flare and cells. In this prospective study laser photometry was used to document the recovery of the blood-aqueous barrier in 27 normal eyes following cataract surgery. Aqueous flare and cells were highest on the first postoperative day, declining rapidly in the first week and returning to preoperative levels by 3 mo...
متن کاملCorrelations between laser flare measurements and anterior chamber protein concentrations.
The laser flare cell meter quantifies anterior chamber (AC) protein (flare) by measuring light scattering of a helium-neon laser beam in the AC. The relationship between photon count and protein concentration both in vitro and in vivo was assessed. The reproducibility of the in vitro photon count measurements was 7.3%. There was a significant linear relationship between photon count and the con...
متن کاملA Rayleigh Scatter-Based Ocular Flare Analysis Meter for Flare Photometry of the Anterior Chamber.
PURPOSE Existing flare photometers are based on the Tyndall effect, which requires sophisticated laser photometry. The ocular flare analysis meter (OFAM) is a nonlaser photometer that uses quantitative Rayleigh scatter and absorption from visible light to compute a flare value. This study is designed to correlate OFAM measurements with qualitative measurements of flare in vitro and in vivo. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Türk Oftalmoloji Dergisi
سال: 2015
ISSN: 1300-0659
DOI: 10.4274/tjo.43434