Distortional Buckling Analysis of Steel-Concrete Composite Girders in Negative Moment Area
نویسندگان
چکیده
منابع مشابه
Strengthening of Scaled Steel-Concrete Composite Girders and Steel Monopole Towers with CFRP
Cost-effective rehabilitation and/or strengthening of steel structures currently demanded by the telecommunications industry and transportation departments. Rehabilitation is often required due to crosssection losses resulting from corrosion damage and strengthening may be required due to changes in the use of a structure. Current strengthening techniques, have several disadvantages including t...
متن کاملLocal and Distortional Buckling of Cold-Formed Steel Members
Laminar structures have a high post-buckling strength reserve. Cold-formed steel profiles can be taken as a set of thin plate elements. Therefore it is necessary to design this type of profiles taking into account that reserve of strength in post-local buckling modes of failure. The method normally used to design this type of structures is based on the Effective Width concept. The Effective Wid...
متن کاملBehavior of Steel–Concrete Composite Beams with Corroded Shear Studs Under Negative Bending Moment
The behavior of corroded steel–concrete composite beams under hogging moment was studied by experimental investigation and theoretical analysis. A total of eight specimens, six of which had corroded shear studs, were tested. The corrosion rate of studs ranged from 0 to approximately 50%. The constant-current accelerated corrosion method was adopted to accelerate the corrosion process. The loadi...
متن کاملFoam Concrete Precast Elements in Composite Concrete-GFRP Plate Girders
This paper is focused on using foam concrete as structural element in polymer-concrete composite plate girders. Trial mixes of foam concrete and different proportions of foam agent were considered to obtain the suitable mix that can be used as structural element in composite girders system. Details of the experimental investigations on foam concrete precast slabs and polymer-concrete composite ...
متن کاملDistortional Buckling Tests on Cold-Formed Steel Beams
Failure in cold-formed steel beams is generally initiated by one of three instabilities: local, distortional, or lateral-torsional buckling. For cold-formed steel joists, purlins, or girts, when the compression flange is not restrained by attachment to sheathing or paneling, distortional buckling may be the predominant failure mode. Experimental results on cold-formed steel beams with unrestrai...