Distortion Correction in EPI Using an Extended PSF Method with a Reversed Phase Gradient Approach
نویسندگان
چکیده
منابع مشابه
Distortion Correction in EPI Using an Extended PSF Method with a Reversed Phase Gradient Approach
In echo-planar imaging (EPI), such as commonly used for functional MRI (fMRI) and diffusion-tensor imaging (DTI), compressed distortion is a more difficult challenge than local stretching as spatial information can be lost in strongly compressed areas. In addition, the effects are more severe at ultra-high field (UHF) such as 7T due to increased field inhomogeneity. To resolve this problem, two...
متن کاملCorrection of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach.
OBJECTIVE This study investigates the application of a modified reversed gradient algorithm to the Propeller-EPI imaging method (periodically rotated overlapping parallel lines with enhanced reconstruction based on echo-planar imaging readout) for corrections of geometric distortions due to the EPI readout. MATERIALS AND METHODS Propeller-EPI acquisition was executed with 360-degree rotationa...
متن کاملAccelerating Data Acquisition for Reversed-gradient Distortion Correction in Diffusion Mri: a Constrained Reconstruction Approach
Introduction – The EPI readouts used to acquire most diffusion weighted images (DWIs) are well known to produce localized geometric distortions in the presence of B0 field inhomogeneity. These artifacts, which manifest as local stretching or compression of the image along the phase encoding (PE) direction, are problematic when attempting to co-register diffusion images with other scans or attem...
متن کاملImproved PSF-based EPI Distortion Correction in Human Imaging at 7 Tesla
M-H. In, J-Y. Jung, S-H. Oh, M. Zaitsev, Z-H. Cho, and O. Speck Department Biomedical Magnetic Resonance, Institute for Experimental Physics, Otto-von-Guericke University Magdeburg, Magdeburg, Germany, Neuroscience Research Institute, Gachon University of Medicine and Science, Inchoen, Korea, Republic of, Department of Radiologic Research, Medical Physics, University Hospital Freiburg, Freiburg...
متن کاملImplementation and Application of PSF-Based EPI Distortion Correction to High Field Animal Imaging
The purpose of this work is to demonstrate the functionality and performance of a PSF-based geometric distortion correction for high-field functional animal EPI. The EPI method was extended to measure the PSF and a postprocessing chain was implemented in Matlab for offline distortion correction. The correction procedure was applied to phantom and in vivo imaging of mice and rats at 9.4T using d...