Distinguishing metabolic heat from condensation heat during muscle recovery.
نویسندگان
چکیده
منابع مشابه
Distinguishing metabolic heat from condensation heat during muscle recovery.
When a thermopile is used to measure the heat production of isolated muscle, the muscle is surrounded by gas saturated with water vapour, initially in equilibrium with the muscle. After contraction, the osmolarity of the muscle is raised so that it is no longer in equilibrium with the gas around it, and condensation will occur. When artificial muscles of known osmolarity were placed on a thermo...
متن کاملMetabolic heat production of neonatal calves during hypothermia and recovery.
Metabolic heat production and rectal temperature were measured in 19 newborn calves (41.8 +/- 3.7 kg) during hypothermia and recovery when four different means of assistance were provided. Hypothermia of 30 degrees C rectal temperature was induced by immersion in 18 degrees C water. Calves were rewarmed in a 20 to 25 degree C air environment where thermal assistance was provided by added therma...
متن کاملHeat production and oxygen consumption during metabolic recovery of white muscle fibres from the dogfish Scyliorhinus canicula.
Oxygen consumption and heat production were measured during contraction and recovery of isolated, white muscle fibres from dogfish (Scyliorhinus canicula) at 19 degrees C. The contraction period consisted of 20 isometric twitches at 3 Hz; this was followed by a recovery period of 2 h without stimulation. We tested the hypothesis that recovery is wholly oxidative (not glycolytic) in these fibres...
متن کاملMetabolic and electrolyte abnormalities during heat exhaustion.
Accepted 27 September 1995 An 81-year-old man, resident of a poorly ventilated, ineffectively air-conditioned inner city apartment, presented during a heat wave (environmental temperature 80°-93°F and humidity 70%-80%) with hyperthermia, confusion and dehydration. The patient had mild hypertension, depression and urinary incontinence and was taking hydrochlorothiazide/methyldopa, nortriptyline ...
متن کاملHeat Transfer and Pressure Drop During HC-600a (Isobutane) Condensation Inside a Brazed Plate Heat Exchanger
This paper presents the heat transfer coefficients and the pressure drop measured during HC-600a (Isobutane) condensation inside a brazed plate heat exchanger: the effects of saturation temperature, refrigerant mass flux and vapour super-heating are investigated. The heat transfer coefficients show weak sensitivity to saturation temperature and great sensitivity to refrigerant mass flux. At low...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Experimental Biology
سال: 1998
ISSN: 1477-9145,0022-0949
DOI: 10.1242/jeb.201.17.2553