Distinct difference offlaAgenotypes ofLegionella pneumophilabetween isolates from bath water and cooling tower water
نویسندگان
چکیده
منابع مشابه
Legionella adelaidensis, a new species isolated from cooling tower water.
A Legionella-like organism (strain 1762-AUS-E) was isolated from a cooling tower of an air-conditioning system in Adelaide, South Australia, Australia. The isolate was presumptively identified as a Legionella strain by its growth requirement for L-cysteine and its cellular branched-chain fatty acids. Strain 1762-AUS-E was serologically distinct in the slide agglutination test with absorbed anti...
متن کاملIsolation of Legionella pneumophilia from cooling tower water by filtration.
Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.
متن کاملOptimization of Water - Cooled Chiller – Cooling Tower Combinations
Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...
متن کاملFactors stimulating propagation of legionellae in cooling tower water.
Our survey of cooling tower water demonstrated that the highest density of legionellae, >/=10 CFU/100 ml, appeared in water containing protozoa, >/=10 MPN/100 ml, and heterotrophic bacteria, >/=10 CFU/100 ml, at water temperatures between 25 and 35 degrees C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 10 CFU/100 ml, occurs in summer. The counts...
متن کاملEnumeration of Legionella pneumophila in cooling tower water systems.
Legionella pneumophila, the causative agent of Legionnaires' disease, is known to colonise and frequently grow in cooling tower waters. Disease is acquired by inhaling aerosol contaminated by legionellae. Determination of the count of Legionella pneumophila in cooling tower waters may, therefore, be useful for risk assessment. In our survey, 103 water samples from 50 cooling towers were examine...