Distal Ulna Hook Plate: Angular Stable Implant for Fixation of Distal Ulna
نویسندگان
چکیده
منابع مشابه
Distal ulna hook plate fixation for unstable distal ulna fracture associated with distal radius fracture.
The significance of distal ulna fractures is often undermined, which can result in inadequate treatment compared with fractures of the radius, the ulna's larger counterpart. However, little guidance exists in the current literature on how to manage distal ulna head or neck fractures and intra-articular ulna head fractures. Therefore, the purpose of this retrospective study was to evaluate the o...
متن کاملInternal fixation after intra-articular fracture of the distal ulna.
We describe a patient who sustained a displaced isolated intra-articular fracture of the distal ulna, causing limitation of rotation of the forearm. The extent of displacement of the fracture which was not evident on plain radiographs was revealed by CT. The fracture was reduced and internally fixed using a standard technique applicable to the fixation of fractures of the radial head. Full move...
متن کاملOutcome following acute primary distal ulna resection for comminuted distal ulna fractures at the time of operative fixation of unstable fractures of the distal radius.
Optimal acute management of the highly comminuted distal ulna head/neck fracture sustained in conjunction with an unstable distal radius fracture requiring operative fixation is not well established. The purpose of the present study was to determine the clinical, radiographic, and functional outcomes following acute primary distal ulna resection for comminuted distal ulna fractures performed in...
متن کاملLocking compression plate distal ulna hook plate fixation versus intramedullary screw fixation for displaced avulsion fifth Metatarsal Base fractures: a comparative retrospective cohort study
BACKGROUND Intramedullary screw (IMS) fixation was wildly used in fifth metatarsal base fractures (FMBFs) and the results were satisfactory. However, in the comminuted osteoporosis or small displaced avulsion FMBFs, anatomical reduction and stable fixation could not be achieved with IMS. The Locking Compression Plate (LCP) distal ulna hook plate fixation was a novel alternative fixation method....
متن کاملClavicular Hook Plate: A Better Implant Choice for Fixation of Unstable Distal Clavicle Fractures?
1878-3317/$ e see front matter Copyright 2012, Ta http://dx.doi.org/10.1016/j.jecm.2012.09.002 Background: The ideal fixation method for unstable distal clavicle fractures is still controversial. Clavicular hook plates (HPs) are an effective option but the clinical efficacy and advantages/disadvantages of this implant compared with the tension band wire technique in treating this fracture have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Wrist Surgery
سال: 2013
ISSN: 2163-3916,2163-3924
DOI: 10.1055/s-0032-1333427