Dissolved Oxygen Control of Batch Bioreactor using Model Reference Adaptive Control scheme
نویسندگان
چکیده
منابع مشابه
Analysis of Speed Control in DC Motor Drive Based on Model Reference Adaptive Control
This paper presents fuzzy and conventional performance of model reference adaptive control(MRAC) to control a DC drive. The aims of this work are achieving better match of motor speed with reference speed, decrease of noises under load changes and disturbances, and increase of system stability. The operation of nonadaptive control and the model reference of fuzzy and conventional adaptive contr...
متن کاملSensorless Model Reference Adaptive Control of DFIG by Using High Frequency Signal Injection and Fuzzy Logic Control
In this paper, a new sensorless model reference adaptive method is used for direct control of active and reactive power of the doubly fed induction generator (DFIG). In order to estimate the rotor speed, a high frequency signal injection scheme is implemented. In this study, to improve the accuracy of speed estimation, two methods are suggested. First, the coefficients of proportional-integral ...
متن کاملModel Reference Adaptive Control
This article presents the elements of model reference adaptive control, which refers to a particular control procedure for uncertain dynamic systems. The control problem as well as the adaptive control problem are described. The use of various models for control, including identification model and reference model is presented. The model-following in the presence of various inputs is discussed. ...
متن کاملHemodynamic Control using Direct Model Reference Adaptive Control Experimental Results
Regulation of hemodynamic parameters is a challenging problem, due to interand intra-patient variability, drug interactions, evolving patient condition, and in the case of simultaneous control of mean arterial pressure and cardiac output, tight coupling between the two variables. This requires a controller that can adapt to conditions as they evolve, and without the need to tune the controller ...
متن کاملCSTR Control by Using Model Reference Adaptive Control and PSO
This paper presents a comparative analysis of continuously stirred tank reactor (CSTR) control based on adaptive control and optimal tuning of PID control based on particle swarm optimization. In the design of adaptive control, Model reference adaptive control (MRAC) scheme is used, in which the adaptation law have been developed by MIT rule & Lyapunov’s rule. In PSO control parameters of PID c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IFAC-PapersOnLine
سال: 2018
ISSN: 2405-8963
DOI: 10.1016/j.ifacol.2018.06.008