Disposable Fluorescence Optical pH Sensor for Near Neutral Solutions

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disposable Fluorescence Optical pH Sensor for Near Neutral Solutions

The design, development and performance evaluation of a fluorescence-based pH sensor for on-line measurements is presented. The pKa of the sensing element has been calculated to be 7.9, thus the sensor is suitable for measurement of near neutral solutions. The sensor consists of a low-cost disposable polymer sensing probe, in contact with the solution under test, interrogated by an optoelectron...

متن کامل

Optical pH Sensor Based on Quinizarin for Alkaline pH Regions

The development of an optical pH sensor based on immobilization of quinizarin (1,4-dihydroxyanthraquinone) on a triacetylcellulose membrane was described. The resulting membrane exhibited fast color change from yellow to violet, while changing the pH in alkaline region. The immobilized quinizarin showed a broader dynamic range from (pH 9.4-11.4) with respect to free form (pH 8.8-10.4). The sens...

متن کامل

Fluorescence resonance energy transfer disposable sensor for copper(II)

A disposable sensor has been developed for the measurement of copper(II) concentration in aqueous solution based on a change in the fluorescence of porphyrazine 2,7,12,17-tetra-tert-butyl-5,10,15,20-tetraaza-21H,23H-porphine (TP). The sensor was constructed by spin-coating a polyester support with a PVC solution containing TP, a plasticizer, the chelating agent Zincon and the ion-pairing benzet...

متن کامل

A potentiometric disposable sensor strip for measuring pH in saliva

In this paper, the preparation of a potentiometric strip for pH monitoring in saliva samples is reported. The potentiometric strip consists of a solid contact pH-selective and of a solidcontact ionogel reference electrode prepared on a dual screen printed substrate. The screen printing protocols, i.e., type of inks and number of deposits, were adjusted to relatively improve the batch reproducib...

متن کامل

Stress- Corrosion Crack Initiation of High-strength Pipeline Steel in Near-neutral pH Environments

Stress-corrosion cracking (SCC) tests were conducted in the near-neutral pH standard solution, NS4, and in an actual soil solution, using four-point bending at a high stress ratio and low frequency conditions very similar to those of operational pipelines. Pitting incubation appeared first and then pitting initiated and grew in both solutions although there were many more pits on the specimen t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2012

ISSN: 1424-8220

DOI: 10.3390/s130100484