Displacement Transducer Using Magnetostrictive Delay Line
نویسندگان
چکیده
منابع مشابه
Magnetostrictive Delay Line Thin Films as Sensing Elements
A miniaturized arrangement based on magnetostrictive delay line (MDL) mechanism, able to be used as sensor, is realized using thin films technology. In order to obtain high-performance miniaturized magnetostrictive delay line arrangement we used Fe, Ni and Fe70B20Si6C4 amorphous thin films as magnetostrictive sensing element because of their better magnetic and magnetoelastic characteristics th...
متن کاملH∞ Control Design for a Magnetostrictive Transducer
Magnetostrictive transducers are becoming increasingly prevalent in industrial applications including high speed milling and hybrid motor design due to their broadband, large force capabilities. To achieve the level of performance required by such applications, however, these transducers must operate in nonlinear and hysteretic regimes. To accommodate this nonlinear behavior, models and control...
متن کاملMicro-Cracks Detection of Eggshells Based on a Magnetostrictive Transducer
With respect to the problem that it is difficult to pick out eggs with small cracks, a novel vibrating type of eggshell cracks detection system using a magnetostrictive transducer was developed firstly. Then the acoustic signals was recorded while the transducer vibrating with the swept frequency from 1 to 14000 Hz. Thirdly, the wavelet and Burg power spectrum were used for data pretreatment an...
متن کاملMagnetostrictive Microcantilever as an Advanced Transducer for Biosensors
The magnetostrictive microcantilever (MSMC) as a high-performance transducer was introduced for the development of biosensors. The principle and characterization of MSMC are presented. The MSMC is wireless and can be easily actuated and sensed using magnetic field/signal. More importantly, the MSMC exhibits a high Q value and works well in liquid. The resonance behavior of MSMC is characterized...
متن کاملThermal noise spectrum of a fiber-optic magnetostrictive transducer.
We report the observation of the thermal equilibrium strain fluctuation spectrum in a transducer using a fiber interferometer. The thermal noise power spectrum in the range of 20-30 kHz of the metallic glass cylinder in this experiment is determined by the dynamic elastic susceptibility and has peak value corresponding to approximately 0.8 microrad/ radicalHZ at 25.5 kHz. The data are analyzed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Society of Instrument and Control Engineers
سال: 1981
ISSN: 0453-4654
DOI: 10.9746/sicetr1965.17.858