Displacement of the Amplatzer occluder device from the mitral paraprosthetic leak.
A critically ill patient had a major mitral paravalvular leak, failed device closure of the leak, and severe hemolytic anemia after a third mitral valve replacement. Echocardiography showed the Amplatzer occluder device completely displaced and swirled in the left atrial cavity. His condition was greatly improved after a fourth mitral valve replacement.
متن کاملA new use for the amplatzer duct occluder device.
We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device emb...
متن کاملParaprosthetic leak unmasked by thrombolysis for thrombosed mitral valve.
Prosthetic valve thrombosis (PVT) is classically a cardiothoracic surgical emergency. Case series, however, report thrombolysis as first line management for PVT. A case of mitral PVT treated successfully with thrombolysis is described. Immediately after thrombolysis a trivial paraprosthetic leak noted on pretreatment transoesophageal echocardiography had increased significantly in severity. The...
متن کاملthe effect of traffic density on the accident externality from driving the case study of tehran
در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...
15 صفحه اولLate Migration of Amplatzer Septal Occluder Device to the Descending Thoracic Aorta
Percutaneous closure of atrial septal defect (ASD) has become an increasingly common procedure. Serious complications of the procedure, such as cardiac migration, are rare, and usually occur <72 hours after device placement. In this report, we present the case of a patient who underwent successful surgical treatment for the migration of an ASD occluder device to the thoracic aorta 12 months aft...