Dispersion Behavior of Solutes in an Ideal Laminar Flow with Small-Bore Glass Tubes
نویسندگان
چکیده
منابع مشابه
Shear dispersion and residence time for laminar flow in capillary tubes
The behaviour of passive tracer particles in capillary Poiseuille flow is investigated with regard to the residence time in short axial sections of length z , in which z /a < Va/D, where a is the capillary radius, V is the mean velocity and D the coefficient of molecular diffusion. While methods exist for calculating moments of the crosssectionally averaged axial concentration distribution as a...
متن کاملSmall-bore chest tubes seem to perform better than larger tubes in treatment of spontaneous pneumothorax.
INTRODUCTION The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). MATERIAL AND METHODS This was a retrospective study of 104 cases (94 patients) of non-traumatic PT treated with chest tubes - either by pulmonary physicians (daytime and we...
متن کاملOptical properties of small-bore hollow glass waveguides.
Hollow glass waveguides with a 250-µm i.d. have been fabricated with a liquid-phase deposition technique that uses silica tubing as a base material. The losses of the 250-µm-bore guide measured at CO(2) laser wavelengths are as low as 2.0 dB/m. The straight losses for the hollow guides are in good agreement with theoretically predicted losses as a result of the nearly ideal structure of the gui...
متن کاملFlow of labeled blood in small cylindrical tubes and glass bead systems.
• The dispersion or smearing out of a bolus of T 1824 injected into the bloodstream continues to be of interest to the physiologist. Considering the curve of distribution of transit times of injected dye through the lesser circulation, how will this curve be distorted by the necessary act of sampling blood from the aortic outflow through a long tube? In a previous paper, experiments were descri...
متن کاملPeak shape and dispersion behavior of solutes in counter-current chromatography with a single phase.
The dispersion behavior of solutes was investigated in a rotating flowing coiled tube. Potassium iodide, tartrazine, ascorbic acid, lysozyme, bovine serum albumin (BSA), and silver nanoparticle (AgNPs) samples were eluted in a coiled tube of counter-current chromatography (CCC) apparatus with a single phase. Apparent convection peaks of low-diffusivity solutes appeared in the static CCC tube, w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the Chemical Society of Japan
سال: 1989
ISSN: 0009-2673,1348-0634
DOI: 10.1246/bcsj.62.1492