Discriminating Method of Islanding for Dispersed Non-utility Generator Interconnected to High-voltage System
نویسندگان
چکیده
منابع مشابه
Inverter based distributed generator islanding detection method using U/O voltage relay
Islanded operation of distributed generators is a problem that can take place when they are connected to a distribution system. In this paper an islanding detection method is presented for inverter based distributed generation (DG) using under/over voltage relay. The method is an adaptive one and is based on the change of DG active power reference (Pref) in inverter control interface. The activ...
متن کاملA new method to determine a well-dispersed subsets of non-dominated vectors for MOMILP problem
Multi-objective optimization is the simultaneous consideration of two or more objective functions that are completely or partially inconflict with each other. The optimality of such optimizations is largely defined through the Pareto optimality. Multiple objective integer linear programs (MOILP) are special cases of multiple criteria decision making problems. Numerous algorithms have been desig...
متن کاملA Novel Method For Islanding Detection Of Distribution System With Distributed Generator
Distributed Generator (DG) is a part of distribution network which is used to supply power both to the local loads and network. DG provides clean energy as it uses pollution free re-newable energy resources to generate power so interest in DG increases. Although DG provides many advantages such as improved reliability, efficiency etc it faces one technical issue called unwanted islanding phenom...
متن کاملdegradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses
در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...
15 صفحه اولUtility of Some Fibrinolytic System Parameters for Differential Diagnosis Between Ischemic and Non-Cardiogenic Chest Pain
The aim of the study is to assess the diagnostic accuracy of some fibrinolytic parameters in the differential diagnosis between patients with unstable angina (UA) and musculoskeletal disorders (MSD). Methods. This cross-sectional study included 119 patients with chest pain (CP) and provisional diagnosis “UA”. After a full set of diagnostic procedures, authors formed 4 groups: patients with isc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1994
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1990.114.7-8_759