Discordant relationship between Essure microinsert position and tubal occlusion.

Hysteroscopic sterilisation with Essure requires confirmation of tubal occlusion by hysterosalpingogram or microinsert position by transvaginal sonography 3 months after placement before women can rely on the method for pregnancy prevention. A 39-year-old woman underwent hysteroscopic sterilisation via Essure, with successful bilateral tubal occlusion documented on hysterosalpingogram. She had ...

متن کامل

Initial experience with hysteroscopic tubal occlusion (Essure®)

OBJECTIVE To evaluate results of early tubal occlusions performed by hysteroscopy (Essure®). METHODS This prospective study included 38 patients, 73.7% of them were white, mean age 34.5 years, they have had on average 3 pregnancies and 2.7 of deliveries. A total of 86.8% of patients previously prepared the endometrium. All procedures were carried out at outpatient unit without anesthesia. R...

متن کامل

Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature

Background. The Essure device is a method of permanent sterilization widely used in the US that has proven to be safe and effective in most cases. However, there have been reports of device migration that have led to failed tubal occlusion as well as several other serious complications resulting from the presence of the device in the abdominal cavity. Case. This paper represents two cases of fa...

متن کامل

Risk of Essure microinsert abdominal migration: case report and review of literature

PURPOSE To report a case of Essure microinsert abdominal migration and literature review. METHODS A 41-year-old woman was counseled to undergo Essure sterilization. The procedure was hampered by the presence of endometrial cavity adhesions, obscuring left tubal ostium. By using microscissors the adhesions were progressively lysed. Since the procedure had become very painful, the patient requi...

متن کامل

the relationship between critical thinking and reading strategies

during the process of reading, sometimes learners use ineffective and inefficient strategies and some factors may influence their use of strategies. perhaps critical thinking is one of these factors. this study aims to identify those categories of reading strategies that are mostly used by iranian efl learners and to see if there is any significant relationship between the critical thinking abi...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMJ Case Reports

سال: 2016

ISSN: 1757-790X

DOI: 10.1136/bcr-2016-216535