Direct digital radiography versus conventional radiography for estimation of canal length in curved canals
نویسندگان
چکیده
منابع مشابه
Direct digital radiography versus conventional radiography for estimation of canal length in curved canals
PURPOSE The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. MATERIALS AND METHODS Sixty molar teeth were selected and divided into three groups in the basis of canal curves (0-15°, 15-30°, >30°). After the placement of a 15 K-file, radiographs were taken with a conventional film (F-speed) and a digital sen...
متن کاملLinear measurements to determine working length of curved canals with fine files: conventional versus digital radiography.
This in vitro study compared conventional and digital radiographic linear measurements to determine the working length (WL) of curved canals with fine endodontic files. In total, 30 mesiobuccal root canals in molars were measured with a #06 K-file to a length 1 mm short of the apical foramen (WL1). Teeth were mounted in plastic blocks and standardized periapical radiographs were obtained by con...
متن کاملDigital Radiography Versus Conventional Radiography in Dentistry
Belma Muhamedagic, Lejla Muhamedagic Faculty of Medicine, University of Sarajevo, Bosnia and Herzegovina ography-RVG, Trophy Radiologie, Croissy Beaubourg, France [now Trophy, A Kodak Company, Rochester, N.Y.]). RVG is modern diagnostic method based on use of digital roentgen. Principle is use of so called CCD chip in RVG sensor (Figure 1) that put in patient’s mouth (3). The first dental digit...
متن کاملRadiovisiography versus Conventional Radiography for Estimation of Canal Length: an in Vitro Study
The aim of this study was to compare the accuracy of the Radiovisiography (RVG) with conventional Radiographic in canal length estimation in vitro for root canal treatment. Forty-single-rooted teeth were endodontically assessed and working lengths were determined using both conventional intra-oral dental film and Radiovisiography (RVG) 1R1X 70 intra-oral x-ray system. Measurement assessment was...
متن کاملComparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Imaging Science in Dentistry
سال: 2011
ISSN: 2233-7822
DOI: 10.5624/isd.2011.41.1.7