Direct determination of trace lithium in serum by graphite furnace AAS.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct determination of zinc in serum by Zeeman atomic absorption spectrometry with a graphite furnace.

We developed a precise and accurate graphite furnace atomic absorption spectrometric method for the direct determination of zinc in serum. Serum samples are analyzed after 20-fold dilution with water of ultrapure analytical grade. No other reagent is used, from the moment of sampling until measurement. During atomization, the argon flow is kept at 150 mL/min instead of gas stop, to decrease the...

متن کامل

Determination of Trace Elements in Rice Products by Flame and Graphite Furnace Atomic Absorption Spectrometry

The Thermo Scientific iCE 3000 Series Atomic Absorption Spectrometers are the ideal tool for the accurate and rapid determination of multiple trace elements in rice products. Flame atomic absorption can be used as a fast screening tool for the analysis of nutritional elements such as copper, manganese and zinc, while graphite furnace atomic absorption can be used for the accurate determination ...

متن کامل

DEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE

Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...

متن کامل

Multivariate Optimization in the Direct Determination of Antimony and Chromium in Serum Samples by Graphite Furnace Atomic Absorption Spectrometry

Methods for direct determination of antimony and chromium in human serum by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) were proposed in this work. The samples were diluted in 1:1 with nitric acid 1% v/v and Triton® X-100 0.1% v/v. The optimization of the instrumental conditions was done using a multivariate approach. A factorial design (2) was employed to investigate the tendency ...

متن کامل

Direct Determination of Tin in Human Hair by Graphite Furnace Atomic Absorption Spectrometry Using Air Ashing in Graphite Tube

Direct determination of tin in human hair was performed by graphite furnace atomic absorption spectrometry. Human hair was cut into 3-5 mm long and 1-2 mg of the sample was directly introduced into a pyrolytically coated graphite tube, of which the injection hole was enlarged to a diameter of approximately 5 mm. After introduction of the sample, 20 μl of 30 mg Pd/l in 1 mol/l HCl was added as a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1987

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.36.7_416