Direct Comparison of 2 Rule-Out Strategies for Acute Myocardial Infarction: 2-h Accelerated Diagnostic Protocol vs 2-h Algorithm
نویسندگان
چکیده
منابع مشابه
Prospective external validation of an accelerated (2-h) acute coronary syndrome rule-out process using a contemporary troponin assay
BACKGROUND Recently there have been efforts to derive safe, efficient processes to rule out acute coronary syndrome (ACS) in emergency department (ED) chest pain patients. We aimed to prospectively validate an ACS assessment pathway (the 2-Hour Accelerated Diagnostic Protocol to Assess Patients with Chest Pain Symptoms Using Contemporary Troponins as the Only Biomarker (ADAPT) pathway) under pr...
متن کاملEarly Rule-Out and Rule-In Strategies for Myocardial Infarction.
BACKGROUND Patients with chest pain comprise a large proportion of emergency presentations and place a major burden on healthcare resources. Therefore, efforts to safely and rapidly identify those with and without acute myocardial infarction (AMI) are needed. The challenge for clinicians is to accurately identify patients with acute coronary syndromes, while balancing the need to safely and rap...
متن کاملPREPARATION AND CHARACTERIZATION OF [Ni (MAP) ] ; H- MAP = 2- (METHYLAMINO) PYRIDINE H. Aghabozorg* and H. H. Monfared
We have recently synthesized [Ni (MAP) ] complex [H-MAP= 2- (methylamino) pyridine]. 2- (Methy1amino)pyridine reacts with MeLi in THF and generates the lithium salt (Li-MAP). Further reaction of NiCl with two equivalent of this ligand in THF leads to the formation of a dark red solution. Analytical data, molecular weight, and magnetic susceptibility of this complex confirm the formula [N...
متن کاملKinetics of HO 2 + HO 2 ! H 2 O 2 + O 2 : Implications for Stratospheric H
[1] The reaction HO2 + HO2 ! H2O2 + O2 (1) has been studied at 100 Torr and 222 K to 295 K. Experiments employing photolysis of Cl2/CH3OH/O2/N2 and F2/H2/O2/N2 gas mixtures to produce HO2 confirmed that methanol enhanced the observed reaction rate. At 100 Torr, zero methanol, k1 = (8.8 ± 0.9) 10 13 exp[(210 ± 26)/T] cm molecule 1 s 1 (2s uncertainties), which agrees with current recommendations...
متن کاملDirect data - driven H 2 − H ∞ loop - shaping ⋆
In this paper, a direct data-driven approach is proposed to tune fixed-order controllers for unknown stable LTI plants in a mixed-sensitivity loop-shaping problem. The method requires a single set of input-output samples and it is based on simple convex optimization techniques; moreover, it guarantees internal stability as the data-length tends to infinity. Compared to a standard model-based ap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 2017
ISSN: 0009-9147,1530-8561
DOI: 10.1373/clinchem.2016.268359