DiPOLE: a 10 J, 10 Hz cryogenic gas cooled multi-slab nanosecond Yb:YAG laser
نویسندگان
چکیده
منابع مشابه
Progress of the 10 J water-cooled Yb:YAG laser system in RCLF
The high repetition rate 10 J/10 ns Yb:YAG laser system and its key techniques are reported. The amplifiers in this system have a multi-pass V-shape structure and the heat in the amplifiers is removed by means of laminar water flow. In the main amplifier, the laser is four-pass, and an approximately 8.5 J/1 Hz/10 ns output is achieved in the primary test. The far-field of the output beam is app...
متن کامل40-W average power, 30-Hz moving-slab Nd:glass laser.
A moving-slab-geometry Nd:glass laser has been designed and demonstrated. An average power output of 43.8 W has been achieved at 2.76-kW input power and at 2.06% slope efficiency. The moving-slab laser has the potential for scaling to kilowatt average power levels.
متن کاملErbium-Based Gas-Cooled Disk Laser
We report on a novel resonantly-pumped, erbium (Er)-based, gas-cooled disk laser (GCDL) scalable to highaverage power (HAP). The GCDL uses edge-pumped composite laser disks known for their near perfect pump uniformity and compact configuration. Edge pumping enables a long path for pump absorption, which permits using low Er concentration and limits upconversion losses. Resonant operation reduce...
متن کامل10-Gb/s Agile Wavelength Conversion With Nanosecond Tuning Times Using a Multisection Widely Tunable Laser
Simultaneous wavelength conversion and high-speed wavelength switching has been demonstrated using a multisection grating-assisted coupler sampled reflector laser. A high-output extinction ratio ( 20 dBm) over a 30-nm wavelength range was observed. The 10-Gb/s data was switched between different output wavelengths at a 2.5-Gb/s rate and transmitted over 50 km of dispersion-shifted fiber with a ...
متن کاملA 10 Hz, 3 microjoule transient soft X-ray laser pumped in grazing incidence
We present recent results on the extensive investigation of a Ni-like Mo X-ray laser pumped in the transient regime and GRIP (grazing incidence pumping) configuration. The pump laser was the 10 Hz, multi-terawatt, Ti:Sa laser system at Lund Laser Centre, Sweden. The main diagnostic was a monochromatic near-field imaging system with a 1.7 micron spatial resolution. Intense lasing was observed ro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2015
ISSN: 1094-4087
DOI: 10.1364/oe.23.019542