Digital video recording in trauma surgery using commercially available equipment

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital video recording in trauma surgery using commercially available equipment

INTRODUCTION Although videos of surgical procedures are useful as an educational tool, the recording of trauma surgeries in emergency situations is difficult. We describe an inexpensive and practical shooting method using a commercially available head-mounted video camera. METHODS We used a ContourHD 1080p Helmet Camera (Contour Inc., Seattle, Washington, USA.). This small, self-contained vid...

متن کامل

Reconfigurable RF Systems Using Commercially Available Digital Capacitor Arrays

Various RF circuit blocks implemented by using commercially available MEMS digital capacitor arrays are presented for reconfigurable RF systems. The designed circuit blocks are impedance-matching network, tunable bandpass filter, and VSWR sensor. The frequency range of the designed circuits is 0.4-4GHz. The MEMS digital capacitor arrays that are employed in the designs have built-in dc-to-dc vo...

متن کامل

Forensic Examination of CCTV Digital VTR Surveillance Recording Equipment

Approximately two years ago I authored a paper entitled, “The Forensic Examination of Video Recordings” which discussed some of the more conventional forensic techniques for examining questioned analog videotapes regarding their originality and for possible evidence of tape alteration. This paper specifically addressed the various mechanical and electrical signal anomalies that occur when editi...

متن کامل

Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera

PURPOSE In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC-408 plastic scintillator, a commercial camera, and a computer. METHODS The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose-rate, and proton energy were determined. Photogr...

متن کامل

P1: Intracranial Recording Surgery

لطفاً به چکیده انگلیسی مراجعه شود.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine

سال: 2013

ISSN: 1757-7241

DOI: 10.1186/1757-7241-21-27