Digital Current Measurement Element for Operation During Current Transformer Severe Saturation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artificial Intelligence Based Approach for Identification of Current Transformer Saturation from Faults in Power Transformers

Protection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, proper and quick identification of Current transformer saturation is so important. In this paper, an Artificial Neural Network...

متن کامل

Mitigation Transformer Inrush Current Using Modified Transient Current Limiter

This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...

متن کامل

Current Transformer Saturation Detection Using Gaussian Mixture Models

This paper presents a novel current transformer (CT) saturation detection approach based on Gaussian Mixture Models (GMMs). High accuracy is the advantage of this method. GMMs are trained with secondary current of CT. The appropriate performance of the proposed method is tested by simulation of different fault conditions in PSCAD/EMTDC software. The results show that the trained GMMs can succes...

متن کامل

artificial intelligence based approach for identification of current transformer saturation from faults in power transformers

protection systems have vital role in network reliability in short circuit mode and proper operating for relays. current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. therefore, proper and quick identification of current transformer saturation is so important. in this paper, an artificial neural network...

متن کامل

Current Measurement with Optical Current Transformer. J World Elec. Eng. Tech., 4 (1): 29-35

The development of power electrical systems causes attention to accuracy of protection elements and measurement values. So we need some new measuring devices with high accuracy for power transmission lines. One of these devices is Optical Current Transformer (OCT). Optical current transformers are suitable for power system protection and can replace the magnetic current transformers. In this pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations

سال: 2018

ISSN: 2414-0341,1029-7448

DOI: 10.21122/1029-7448-2018-61-6-483-493