Digital Control of Pneumatic Cylinder

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pneumatic Cylinder Control Pid for Manipulator Robot

This work shows a controller development for cylinder penumatic, that due to compressibility air characteristics, present a non linear behavior. Is including the develop of PID, discreete PID and Fuzzy Logic approximation, as solution to the problem. The work is part of a major project of Flexible Manipulator Robot, with dielectrics characteristics, for cleaning of porcelain isolators of high v...

متن کامل

Precision Position Tracking of Mr-compatible Pneumatic Piston-cylinder Using Sliding Mode Control

This paper presents the nonlinear dynamics and sliding mode control design for a 1-DOF needle insertion robot. The robot actuator is an MR-compatible pneumatic piston-cylinder. A brief review of the dynamics for this type of actuator is provided. The reaction force of tissue on the needle remains an unknown for which our controller compensates. A sliding mode control law is formulated that reli...

متن کامل

Design and simulation of a distortion masking control algorithm for a pneumatic cylinder

.............................................................................................................................. xxiii CHAPTER

متن کامل

Design of Upper Limb Assistive Device Using a Pneumatic Cylinder

This paper describes the design of a device to support a patient’s upper limb motion. For safety, light weight, and flexibility, it uses a pneumatic cylinder for which the optimum arrangement is presented. This independencesupporting device has two modes corresponding to livelihood support and rehabilitation. Based on human motion, a compliance control system and a position control system are d...

متن کامل

Development of Flexible Pneumatic Cylinder with Backdrivability and Its Application

In the remote controlled rehabilitation device, physical therapists must recognize the situation of the patient. The actuator in the device is also required to be flexible so as not to injure the body. In our previous study, the flexible pneumatic cylinder was proposed and tested. The flexible robot arm using the cylinders for human wrist rehabilitation was also developed. In the next step, it ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Transactions of the Society of Instrument and Control Engineers

سال: 1990

ISSN: 0453-4654

DOI: 10.9746/sicetr1965.26.397