Diffraction Methods of Measuring Red Cell Diameters
نویسندگان
چکیده
منابع مشابه
measuring viscoelastic properties of Red Blood Cell using optical tweezers
Efforts have been made to study the behavior of complex materials in micrometer dimensions with various techniques. One of these methods is the use of optical tweezers for biophysical applications. Red blood cells, as the most abundant blood-forming cells, play an important role in the life of living organisms, and their unique mechanical properties are important. In this report, the study of s...
متن کاملA microtechnique for measuring red cell osmotic fragility of infants.
Chloramphenicol (D-threo-2-dichloroacetamido-1-p-nitrophenylpropane-1,3-diol) added to blood samples did not alter the observed shift in the red cell osmotic fragility curves as the samples were aged in vitro for 24 hours at 37 degrees C. Nor was the normal rate of loss of 2,3-diphosphoglycerate, ATP, or glutathione from the red cells affected by the presence of chloramphenicol over the same pe...
متن کاملMeasuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry.
Decreased red cell deformability is characteristic of several disorders. In some cases, the extent of defective deformability can predict severity of disease or occurrence of serious complications. Ektacytometry uses laser diffraction viscometry to measure the deformability of red blood cells subject to either increasing shear stress or an osmotic gradient at a constant value of applied shear s...
متن کاملMeasuring Red Blood Cell Velocity with a Keyhole Tracking Algorithm
A tracking algorithm is proposed to measure the velocity of red blood cells traveling through microvessels of tumors growing in skin flaps implanted on mice. The tracking is based on a keyhole model that describes the probable movement of a segmented cell between contiguous frames in a video sequence. When a history of movements exists, past, present and a predicted landing position define two ...
متن کاملNew direct method for measuring red cell lithium.
A new direct method for the measurement of red cell lithium was compared with the indirect method. Good correlation (r = 0.97) was found and the coefficients of variation of the direct and indirect methods were 3.9% and 5.5%, respectively. In the direct method red cells suspended in choline chloride were centrifuged through dibutyl phthalate, which removes plasma adherent to the cells. A haemol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMJ
سال: 1949
ISSN: 0959-8138,1468-5833
DOI: 10.1136/bmj.2.4643.1506