Diffraction data deposition
نویسندگان
چکیده
منابع مشابه
Automated and accurate deposition of structures solved by X-ray diffraction to the Protein Data Bank.
The RCSB Protein Data Bank (PDB) has a number of options for deposition of structural data and has developed software tools to facilitate the process. In addition to ADIT and the PDB Validation Suite, a new software application, pdb_extract, has been designed to promote automatic data deposition of structures solved by X-ray diffraction. The pdb_extract software can extract information about da...
متن کاملProcessing a multifold ground penetration radar data using common-diffraction-surface stack method
Recently, the non-destructive methods have become of interest to the scientists in various fields. One of these method is Ground Penetration Radar (GPR), which can provide a valuable information from underground structures in a friendly environment and cost-effective way. To increase the signal-to-noise (S/N) ratio of the GPR data, multi-fold acquisition is performed, and the Common-Mid-Points ...
متن کاملDeposition of macromolecular data.
EDWARD N. BAKER,a~ " TOM L. BLUNDELL, b MAMANNAMANA VIJAYAN,C~ ELEANOR DODSON,d§ GUY DODSON,d~ GARY L. GILLILAND e AND JOEL L. SUSSMAN f'g** at aDepartment of Chemistry and Biochemistry, Massey University, Palmerston North, New Zealand, bICRF Unit of Structural Molecular Biology Department of Crystallography, Birkbeck College, Malet St, London, WC1E 7HX, England, CMolecular Biophysics Unit, Ind...
متن کاملIntegration of macromolecular diffraction data.
Diffraction intensities can be evaluated by two distinct procedures: summation integration and profile fitting. Equations are derived for evaluating the intensities and their standard errors for both cases, based on Poisson statistics. These equations highlight the importance of the contribution of the X-ray background to the standard error and give an estimate of the improvement which can be a...
متن کاملX-ray Diffraction Data Collection
“point” and “area” (originally film) detectors. The first X-ray diffraction experiment by Friedrich and Knipping [1] used film, but within the same year Bragg was using an ionization chamber mounted on a rotating arm [2]. The advantage of Bragg's X-ray detector was that it defined precisely the angle of the diffracted rays and, in general, gave more accurate intensity measurements. The advantag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Structure
سال: 1996
ISSN: 0969-2126
DOI: 10.1016/s0969-2126(96)00024-x