Difficulty in withdrawal of a sutured pulmonary artery catheter with blood leaking from pulmonary artery catheter connection port
نویسندگان
چکیده
منابع مشابه
[A unique case of pulmonary artery catheter bleeding from the oximetry connection port].
Pulmonary artery catheter is an invasive monitor usually placed in high-risk cardiac surgical patients to optimize the cardiac functions. We present this case of blood oozing from the oximetry connection port of the pulmonary artery catheter that resulted in the inability to monitor continuous cardiac output requiring replacement of the catheter. The cause of this abnormal bleeding was later co...
متن کاملunexpected collection of pulmonary venous blood from a pulmonary artery catheter: a case report
conclusions our case highlights the fact that the tip of the pulmonary artery catheter can easily advance into a peripheral branch of the pulmonary artery and cause pulmonary venous blood to be sampled instead of pulmonary arterial blood. a variety of monitoring techniques are needed to confirm accurate catheter placement. background pressure and waveform at the catheter tip are continuously mo...
متن کاملThe pulmonary artery catheter.
Clinical Medicine Vol 2 No 2 March/April 2002 101 The flow-directed pulmonary artery catheter (PAC) has been in clinical use since its introduction by Swan and colleagues in 19701. During that time it has become widely used in critical care units throughout the world and is now the most commonly utilised form of flow monitoring. The haemodynamic data obtained with a PAC are used to monitor and ...
متن کاملPulmonary artery catheter-induced hemorrhage.
Pulmonary artery rupture by a flow-directed balloon-tipped catheter is a rare complication if guidelines for insertion of catheters are strictly applied. It should be stressed that the need for a "confirmed" wedge pressure should be weighed against the very real risk of this potentially fatal complication. Users of this catheter should expect and anticipate distal migration of the catheter tip....
متن کاملA misplaced and entrapped pulmonary artery catheter
Corresponding author: Ho-Geol Ryu, M.D., Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, 101, Daehag-ro, Jongro-gu, Seoul 110-744, Korea. Tel: 82-2-2072-2065, Fax: 82-2-747-5639, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/b...