Difficult Airway Management and Laryngeal Mask Airway

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Difficult Laryngeal Mask Airway Placement.

Laryngeal mask airway (LMA), which consists of a silicone tube connected to a miniature silicone mask appropriate for the shape of hypopharynx and covers the larynx as a gasket, was developed in 1980s in the United Kingdom. It is frequently used both to avoid negative effects of endotracheal intubation by establishing direct connection with the airway of patient and to easily provide a more rel...

متن کامل

Emergency airway management with laryngeal mask airway.

When used correctly, laryngeal mask airway is a life saver. We report two cases wherein it was used for rescue airway management and as a ventilatory device during anesthesia. It is concluded that an anesthetist should be familiar with the use of this device.

متن کامل

Laryngeal mask airway: an alternative for the difficult airway.

The laryngeal mask airway (LMA) was invented by Dr. Archie Brain at the London Hospital, Whitechapel, in 1981. Dr. Brain's main objective for the LMA was that it would provide a better method of maintaining a patient's airway than by face mask. Also, the LMA would be less hemodynamically stressful than with insertion of an endotracheal tube. The LMA consists of a silicone rubber tube connected ...

متن کامل

Using the laryngeal mask airway to manage the difficult airway.

Before 1990, the choice of an airway device essentially was limited to the facemask or the endotracheal tube. Since then, a number of novel supraglottic airway devices have been developed. The laryngeal mask airway (LMA) was introduced to the United States in 1991 after 3 years of use in the United Kingdom and other countries. Today the LMA has a clearly established role as an airway device in ...

متن کامل

The laryngeal mask airway: its role in the difficult airway.

The laryngeal mask airway (LMA) is a relatively new device that was brought into clinical practice in the 1980s. It was conceived, designed, and developed between 1981 and 1988 by Dr. Archie Brain, a British anesthesiologist who felt that a component for airway management was missing. The laryngeal mask was conceived to provide the bridge between the face mask and the endotracheal tube. The con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: THE JOURNAL OF JAPAN SOCIETY FOR CLINICAL ANESTHESIA

سال: 2010

ISSN: 0285-4945,1349-9149

DOI: 10.2199/jjsca.30.577