Differential confocal self-collimation method for high-accuracy measurements of lens decentration
نویسندگان
چکیده
منابع مشابه
High accuracy dual lens transmittance measurements.
We show how to determine the transmittance of short focal length lenses (f approximately 19 mm and f approximately 2 5 mm, in this case) with a combined uncertainty of 3 parts in 10(4) or better by measuring transmittances of lens pairs of a set of three or more lenses with the same nominal focal length. Uncertainties are minimized by optimizing the radiometric design of the setup and the measu...
متن کاملLaser differential confocal lens refractive index measurement.
A new laser differential confocal lens refractive index measurement is proposed, which uses the absolute zero of the differential confocal axial intensity curve to precisely identify the positions of the objective when the measurement pencil is focused on the vertex of the test lens and the reflector with or without the test lens in the measurement light-path, and then uses aberration compensat...
متن کاملComparison of intraocular lens decentration and tilt measurements using 2 Purkinje meter systems.
PURPOSE To evaluate the difference in intraocular lens tilt and decentration measurements with 2 Purkinje meters. SETTING Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN Prospective evaluation of diagnostic test. METHODS This single-center study included pseudophakic patients in 2 substudies in which 3 consecutive measurements were performed with...
متن کاملIntraocular lens tilt and decentration measurements: Purkinje imaging versus Scheimpflug imaging
Purpose: To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems. Methods: Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus) and custom algorithms, and a custom-built Purkinje imaging apparatus. Both methods were validated with a physical model eye where tilt and decentration can b...
متن کاملPhakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements.
We present a Purkinje imaging system for phakometry and measurement of tilt and decentration of crystalline and intraocular lenses (IOLs). Crystalline lens radii of curvature were estimated by using both a merit function and the equivalent mirror approaches. Tilts and decentrations were estimated by using Phillips's linear analysis. We present a complete validation of the technique through exha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2020
ISSN: 1094-4087
DOI: 10.1364/oe.389622