Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA
نویسندگان
چکیده
منابع مشابه
Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty.
A major limiting factor in the longevity of total hip replacement is the wear rate of the hip bearing. As manufacturing technology has improved during the past several decades, much attention has been focused on developing newer generations of polyethylene that have lower rates of wear while minimizing free radical formation and subsequent osteolysis. The turning point for the manufacture of po...
متن کاملSequentially Annealed Highly Cross-linked Polyethylene Reduced In Vivo Wear Particle Generation In TKA
Introduction: Polyethylene wear particles induce macrophages to release cytokines, which can lead to osteolysis and aseptic loosening of total joint prostheses. The generation of polyethylene wear particles is one of the most important factors that affect the midterm and long-term clinical results associated with total knee arthroplasty (TKA). Therefore, to achieve better long-term results for ...
متن کاملIn Vivo Wear Particles of Annealed Highly Cross-Linked Polyethylene in Total Hip Arthropalsty
INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...
متن کاملIn Vivo Wear Particles of Remelted Highly Cross-Linked Polyethylene in Total Hip Arthropalsty
INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...
متن کاملWear of moderately cross-linked polyethylene fixed bearing knee replacements
Cross-linked polyethylene has been explored as an alternative to conventional polyethylene in total joint replacement in order to reduce wear volume and decrease failure through polyethylene wear debris induced osteolysis [1]. Due to the demands of a total knee replacement, moderately cross-linked polyethylene is recommended to retain mechanical properties [2]. This study aims to investigate th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Orthopaedic and Trauma Surgery
سال: 2021
ISSN: 0936-8051,1434-3916
DOI: 10.1007/s00402-021-03832-0