Diagnosis of endocardial cushion defect with cross-sectional and M-mode scanning echocardiography. Differentiation from secundum atrial septal defect.
نویسندگان
چکیده
منابع مشابه
Diagnosis of endocardial cushion defect with cross-sectional and M-mode scanning echocardiography. Differentiation from secundum atrial septal defect.
Twelve cases of endocardial cushion defect were studied before and after operation with ultrasono-cardiotomography (tomography) cross-sectional echocardiography, two-dimensional echocardiography, B-scan echocardiography) and M-mode scan along a horizontal section of the heart. For comparison, 20 healthy subjects, 18 cases of mitral valvular disease, 4 cases of congestive cardiomyopathy, 1 case ...
متن کاملSecundum atrial septal defect
A 20-year-old woman presented for evaluation of palpitations and one episode of near syncope after exertion. Her past medical history was remarkable only for a diagnosis of exercise-induced asthma. She was involved in competitive sports at her University, participating on the track team. She denied any chest discomfort, dyspnea at rest, or perceived exercise limitation. She had never had lower ...
متن کاملElectrocardiogram of secumdum type atrial septal defect simulating endocardial cushion defect.
Three groups of patients are identified in the series of secumdum atrial septal defect with left axis deviation in an analysis of 910 patients of secundum atrial septal defect with or without other accompanying anomalies: 1) 12 patients with isolated ostium secumdum defect; 2) 5 patients with associated prolapse of posterior leaflet of the mitral valve; 3) 4 patients with associated hypertrophi...
متن کاملEndocardial Cushion Defect
THE REPAIR of atrial septal defects was first undertaken over a decade ago.1'Although secundum-type defects could be closed adequately without the use of cardiopulmonary bypass, it soon became apparent that defects of the endocardial cushion type were not am-enable to correction by indirect technies.5 Accordingly, the need arose to differentiate these two lesions; the clinical, electrocardiogra...
متن کاملPhonocardiographic analysis of diastolic flow murmurs in secundum atrial septal defect and ventricular septal defect.
The presence oflow frequency diastolic murmurs, presumably due to increased flow through the respective atrio-ventricular valves, has been recognized in patients with atrial and ventricular septal defects for many years. The murmur in ventricular septal defect was reported by Laubry and Pezzi in 1921 and emphasized by Wood (1950). A publication from this institute drew attention to this phenome...