Developments in Salt-Velocity Flow Measurement
نویسندگان
چکیده
منابع مشابه
Simultaneous measurement of water flow velocity with fluorescent and speckle imaging technique
The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...
متن کاملDoppler aortic flow velocity measurement in healthy children.
To determine normal values for Doppler parameters of left ventricular function, ascending aortic blood flow velocity was measured by pulsed wave Doppler echocardiography in 63 healthy children with body surface area (BSA) < 1 m(2) (age < 10 yr). Peak velocity was independent of sex, but increased with body size. Mean acceleration was related to peak velocity (r = 0.75, p < 0.0001). Both stroke ...
متن کاملMeasurement of Velocity and Mass Flow of Powders
− In this paper a cost-effective method for measuring transportation velocity and the velocity profile of a material flow of powdery solids inside a pipe is presented. For the measurement, artificial perturbations are brought into the mass flow and the effects of these perturbations are acquired and correlated at measurement sections. The velocity profile is calculated with the knowledge of the...
متن کاملRapid measurement of pulse wave velocity via multisite flow displacement.
A MR method is presented for measuring pulse wave velocity (PWV) and its application to assessing stiffness in the human thoracic aorta. This one-dimensional (1D) flow displacement method applies a single RF comb excitation to the vessel, followed by an oscillating frequency encoding gradient, each oscillation providing a 1D projection of the vessel, enabling one to track fluid motion. The curr...
متن کاملMeasurement of velocity profiles in multiphase flow using a multi-electrode electromagnetic flow meter
This paper describes an electromagnetic flow meter for velocity profile measurement in single phase and multiphase flows with non-uniform axial velocity profiles. A Helmholtz coil is used to produce a near-uniform magnetic field orthogonal to both the flow direction and the plane of an electrode array mounted on the internal surface of a non-conducting pipe wall. Induced voltages acquired from ...