Development of loop-mediated isothermal amplification (LAMP) for simple detection of Leishmania infection

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electric LAMP: Virtual Loop-Mediated Isothermal AMPlification

We present eLAMP, a PERL script, with Tk graphical interface, that electronically simulates Loop-mediated AMPlification (LAMP) allowing users to efficiently test putative LAMP primers on a set of target sequences. eLAMP can match primers to templates using either exact (via builtin PERL regular expressions) or approximate matching (via the tre-agrep library). Performance was tested on 40 whole ...

متن کامل

Determination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran

Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...

متن کامل

Urine sample used for detection of toxoplasma gondii infection by loop-mediated isothermal amplification (LAMP).

In this study, a loop-mediated isothermal amplification (LAMP) assay was established to detect Toxoplasma gondii DNA in mice infected with T. gondii PRU strain. This LAMP assay was based on the sequence of highly repetitive B1 gene. The detection limit of T. gondii LAMP assay was 1 pg of T. gondii DNA, which was evaluated using 10-fold serially diluted DNA of cultured parasites. The LAMP assay ...

متن کامل

Development and application of loop-mediated isothermal amplification (LAMP) for detection of Plasmopara viticola

A rapid LAMP (loop-mediated isothermal amplification) detection method was developed on the basis of the ITS sequence of P. viticola, the major causal agent of grape downy mildew. Among the 38 fungal and oomycete species tested, DNA isolated exclusively from P. viticola resulted in a specific product after LAMP amplification. This assay had high sensitivity and was able to detect the presence o...

متن کامل

Determination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran

Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Parasites & Vectors

سال: 2015

ISSN: 1756-3305

DOI: 10.1186/s13071-015-1202-x