Condensed matter experiments at high pressure accentuate the need for accurate pressure scales over a broad range of temperatures, as well as placing a premium on a homogeneous pressure environment. However, challenges remain in diamond anvil cell technology, including both the quality of various pressure transmitting media and the accuracy of secondary pressure scales at low temperature. We di...
متن کاملLow-temperature olivine rheology at high pressure
San-Carlos olivine rheology was investigated at pressure (P) up to 9 GPa and temperature (T) lower than 890 ◦C. Six powder specimens were cold compressed and sintered into dense and compact materials, then deformed during relaxation experiments carried out at constant pressure and temperature in DIA-type cubic-anvil apparatus. Sample elastic strain was monitored during relaxation by in situ X-r...
متن کاملConsiderations of Well Cementing Materials in High-Pressure, High-Temperature Conditions (RESEARCH NOTE)
As worldwide demand of hydrocarbon is growing fast, the oil and gas companies have been forced to explore reservoirs with more hostile conditions, such as high-pressure, high-temperature conditions. Improved technology, material selection and testing procedures are required to overcome the common problems in these conditions. One of the main phases of well construction is cementing job. Appropr...
متن کاملDesign, Construction and Testing of a High Temperature High Pressure Spectroscopic Cell for Polymer Physics Studies
OF THE THESIS Design, Construction and Testing of High Temperature-High Pressure Spectroscopic Cell for Polymer Physics Studies by
متن کاملDevelopment of High Pressure Xe Scintillation Proportional Counter for Experiments in ”low-background” Physics
Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The counter can be applied for the experiments in ”low–background” physics which require a low energy threshold. E-mail : akimov [email protected]