Development and Test of Large Size GEM Detectors
We discuss the main operating features of GEM detectors, optimized for use as trackers in a high radiation environment. The construction, tests and performances of large prototypes for the COMPASS experiment are also described, as well as the results of an exposure to very high intensity beams. I. GEM OPERATION AND PERFORMANCES The basic element in GEM detectors is a thin polymer foil, metal-cl...
متن کاملDevelopment of the data acquisition system for the Triple - GEM detectors for
In this contribution we will report on the progress of the design of the readout and data acquisition system being developed for triple-GEM detectors which will be installed in the forward region (1.5 < |η |< 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, expected in the period 2017–2018. The system will be designed to take full advantage of current generic developme...
متن کاملDevelopment of high sensitivity radon detectors
High sensitivity detectors for radon in air and in water have been developed. We use electrostatic collection and a PIN photodiode for these detectors. Calibration systems have been also constructed to obtain collection factors. As a result of the calibration study, the absolute humidity dependence of the radon detector for air is clearly observed in the region less than about 1.6 g/m3. The cal...
متن کاملReadout of GEM Detectors Using the Medipix2 CMOS Pixel Chip
We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron multiplier (Triple-GEM) to detect the ionization from Fe X-rays and electrons from Ru. The device allows to perform moderate energy spectroscopy measurements (20 %...
متن کاملBeam Performance of Tracking Detectors with Industrially Produced GEM Foils
Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm × 10 cm and a two-dimensional, laseretched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab. These detectors used GEM foils produced by Tech-Etch, Inc. They showed an efficiency in excess of 95% and spatial resolution better than 70 μm. The influence o...