Development of Detailed Korean Adult Eye Model for Lens Dose Calculation
نویسندگان
چکیده
منابع مشابه
Calculation of equivalent dose for the lens of the eye in a positron field using EGS5
The equivalent dose rate per positron fluence for the human eye lens is calculated using a Monte Carlo simulation code, EGS5, with two mathematical models (a computational head voxel phantom and a simple eye model). The eye lens doses for medical staff and carers as received from a radiopharmaceutical such as F-FDG, which is used in PET examinations, when spilled on the floor, and from positron...
متن کاملIntraocular lens power calculation for the equine eye.
BACKGROUND Phacoemulsification and intraocular lens (IOL) implantation during cataract surgery in horses occur with increasing frequency. To reduce the postoperative refractive error it is necessary to determine the proper IOL power. In the present study retinoscopy, keratometry and ultrasonographic biometry were performed on 98 healthy equine eyes from 49 horses. The refractive state, corneal ...
متن کاملDevelopment of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کاملDevelopment of an Implicit Numerical Model for Calculation of Sub and Super Critical Flows
A two dimensional numerical model of shallow water equations was developed tocalculate sub and super-critical open channel flows. Utilizing an implicit scheme the steady stateequations were discretized based on control volume method. Collocated grid arrangement was appliedwith a SIMPLEC like algorithm for depth-velocity coupling. Power law scheme was used fordiscretization of convection and dif...
متن کاملNew formula for Calculation of Cobalt-60 Percent Depth Dose
Introduction: On the basis of percent depth dose (PDD) calculation, the application of dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Radiation Protection and Research
سال: 2020
ISSN: 2508-1888,2466-2461