Development of cryogenic cooling system using a double G-M cryo-cooler for NMR spectrometer

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryogenic Cooling System

Printed & published by Dr Mohinder Singh, Director, DESIDOC, on behalf of DRDO. RNI No. 55787/93 Readers of Technology Focus are invited to send their communications to the Editor, Technology Focus DESIDOC, Metcalfe House, Delhi 110 054. India Telephone: 011-23819975; Fax: 011-23819151; Drona-mail: [email protected] E-mail: [email protected], [email protected] Internet: http://www....

متن کامل

How to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier

Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

A Double Pipe Heat Exchanger Design and Optimization for Cooling an Alkaline Fuel Cell System

In the presented research, heat transfer of a mobile electrolyte alkaline fuel cell (AFC) (which the electrolyte has cooling role of system) has been considered. Proper control volumes of system with specific qualification have been chosen. Consequently, heat and mass transfer in control volumes have been assessed. Considerations on them and contributed models lead to approve a double tube heat...

متن کامل

Cryogenic cooling with cryocooler on a rotating system.

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (>99.999%) and high-pressure (1.7 MPa) helium gas and electricity to the cryocooler. The operation of the cryocooler and other instruments requires the development of interfac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2008

ISSN: 1742-6596

DOI: 10.1088/1742-6596/97/1/012232