Development of Amperometric Glucose Biosensor Based on Prussian Blue Functionlized TiO2 Nanotube Arrays
نویسندگان
چکیده
منابع مشابه
Development of Amperometric Glucose Biosensor Based on Prussian Blue Functionlized TiO2 Nanotube Arrays
Amperometric biosensors consisting of oxidase and peroxidase have attracted great attention because of their wide application. The current work demonstrates a novel approach to construct an enzymatic biosensor based on TiO2 nanotube arrays (TiNTs) as a supporting electrode on which Prussian Blue (PB)-an "artificial enzyme peroxidase" and enzyme glucose oxidase (GOx) have been immobilized. For t...
متن کاملAmperometric Biosensor based on Prussian Blue Nanoparticle-modified
25 26 Glucose-6-phosphate (G6P) plays an important role in carbohydrate metabolism of all living 27 organisms. Compared to the conventional analytical methods available for estimation of G6P, the 28 biosensors having relative simplicity, specificity, low-cost and fast response time are a promising 29 alternative. We have reported a G6P biosensor based on screen-printed electrode utilizing 30 Pr...
متن کاملAn amperometric glucose biosensor based on titania sol-gel/Prussian Blue composite film.
An improved amperometric glucose biosensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared by a vapor deposition method, on a Prussian Blue (PB)-modified electrode. The method combined the merits of immobilizing biomolecules in the titania sol-gel film by vapor deposition method and the synergic catalysis effects of PB and GOD molecules. Resul...
متن کاملPlanar Amperometric Glucose Sensor Based on Glucose Oxidase Immobilized by Chitosan Film on Prussian Blue Layer
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV (versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michane...
متن کاملAmperometric biosensor based on Prussian Blue nanoparticle-modified screen-printed electrode for estimation of glucose-6-phosphate.
Glucose-6-phosphate (G6P) plays an important role in carbohydrate metabolism of all living organisms. Compared with the conventional analytical methods available for estimation of G6P, the biosensors having relative simplicity, specificity, low cost, and fast response time are a promising alternative. We have reported a G6P biosensor based on screen-printed electrode using Prussian Blue (PB) na...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2014
ISSN: 2045-2322
DOI: 10.1038/srep06891