Development of a triple coincidence method of reaction, gamma-ray, and weak decay in the hypernuclear gamma-ray spectroscopy at J-PARC

نویسندگان

چکیده

To understand the mechanism of charge symmetry breaking between 4 Λ H and He, we plan to measure gamma-transition energy (1 + → 0 ) with a Ge detector array. For identification hypernucleus, will perform triple coincidence reaction, γ -ray, weak decay for first time. We pion from range counter. This method enable -ray spectroscopy various hyperfragments which cannot be directly produced by ( K − , π or reactions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-Ray Spectroscopy of Gamma-Ray Bursts

Observational evidence of iron absorption and emission lines in X-ray spectra of Gamma-Ray Bursts is quite compelling. I will briefly review the results, summarize different models and describe the connection with massive progenitors in star-forming regions implied by these results. This link is also supported by measurements of the X-ray absorbing gas in several GRB’s, with column density cons...

متن کامل

CdZnTe Gamma Ray Spectrometer for Orbital Gamma Ray Spectroscopy

We present the design and analysis of a new gamma ray spectrometer for planetary science that uses an array of CdZnTe detectors to achieve the detection efficiency needed for orbital measurements. The use of CdZnTe will provide significantly improved pulse height resolution relative to scintillation-based detectors, with commensurate improvement in the accuracy of elemental abundances determine...

متن کامل

Hypernuclear Gamma-Ray Spectroscopy and the Structure of p-shell Nuclei and Hypernuclei

5.1 The Central Interaction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.2 Structure of Li, Li, and Be . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.3 Structure of Be and C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.4 Structure of B and Be . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

متن کامل

Instrumentation for Gamma-Ray Spectroscopy

The subject of ttis chapter is the function and operation of the components of a gamma-ray spectroscopy system. In Chapter 3 it was shown that the output pulse amplitude from most gamma-ray detectors is proportional to the energy deposited by the gamma ray. The pulse-height spectrum from such a detector contains a series of full-energy peaks superimposed on a continuous Compton background. Alth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Epj Web of Conferences

سال: 2022

ISSN: ['2101-6275', '2100-014X']

DOI: https://doi.org/10.1051/epjconf/202227111007