Development of a seismic design system for coaxial cylindrical oil storage tanks.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between Different Editions of API650 Seismic Provisions for Cylindrical Steel Storage Tanks Considering the Fragility Curves

Seismic safety of liquid storage tanks is of considerable importance due to its application in different industries. In Iran, most of these storage tanks are designed based on API650 code provisions. Despite designing tanks according to API standard, the lesson learned from previous earthquakes, shows different kind of damage occurring on them. This study is an investigation on evaluating diffe...

متن کامل

Improving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction

Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...

متن کامل

Design and Study of Floating Roofs for Oil Storage Tanks

Floating roofs are widely used to store petroleum products with high volatility. This is to prevent the product loss and to ensure safe environment around the storage tanks. However, small number of researches were accomplished. These researches aim at study the design of the floating roof and the associated risks that it faces during operation. In an effort to compensate the lack of knowledge ...

متن کامل

Introduction of Air Cushion to Reduce Seismic Demand in Cylindrical Water Storage Tanks

Water storage tanks not designed explicitly for seismic loading could require retrofit. One of the common ways of retrofit include some structural change in the lateral load resisting system that could be expensive and requires the tank to be out of service for relatively long time. This paper introduces a novel method to reduce seismic demand on tank’s wall without structural intervention. Thi...

متن کامل

Fluid damping of cylindrical liquid storage tanks

A method is proposed in order to calculate the damping effects of viscous fluids in liquid storage tanks subjected to earthquakes. The potential equation of an ideal fluid can satisfy only the boundary conditions normal to the surface of the liquid. To satisfy also the tangential interaction conditions between liquid and tank wall and tank bottom, the potential flow is superimposed by a one-dim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A

سال: 1990

ISSN: 0387-5008,1884-8338

DOI: 10.1299/kikaia.56.2601