Development of a Respiration and Cardiac Dynamics Waves Measurement System using Coupled Capacitance Electrode

نویسندگان

چکیده

Recently, the number of health-related car accidents in Japan has been increasing. Most health conditions leading to traffic are detectable by analyzing fluctuation blood pressure. In addition, cardiopulmonary arrest is an important condition that linked and should be studied along with respiration. Therefore, this study proposes a noncontact measurement system for cardiac dynamics respiration using coupled capacitance electrode. The principle electrode utilizes capacitive coupling human body. body, particular heart lung, regarded as dielectric. displacement dielectric indicated changes To validate proposed system, we conducted measurements concurrent chest circumference strain gauge electrocardiographic recording references. results revealed capable measuring dynamics.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Capacitance Measurement System Using an IVD Bridge

A new system to characterize the magnitude and phase characteristics of 1 pF to 1 F capacitance standards over the 50 Hz to 100 kHz frequency range is described. The system has been developed to provide measurement support for LCR meters and general impedance measurement services. It consists of an inductive voltage divider (IVD) bridge capable of accurately comparing two capacitance standards...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

iranian efl learners’ pragmatic development: a study of proficiency and textbook effect

در تحقیق حاضراین پرسش که آیا دانش کاربرد شناسی زبان آموزان ایرانی همگام با پیشرفت بسندگی زبانی آنها افزایش می یابد مورد مطالعه قرار گرفته و هم چنین به این پرسش که آیا زبان آموزان تعلیم دیده از طریق کتاب های تاپ ناچ و اینترچینج تفاوت معناداری از لحاظ سطح دانش کاربرد شناسی دلرند ، پاسخ داده شده است. در این تحقیق55 فراگیر زبان انگلیسی به عنوان زبان دوم ازطریق نمونه گیری در دسترس مورد مطالعه قرار گ...

Low Value Capacitance Measurement System with Adjustable Lead Capacitance Compensation

The present paper describes the development of a low cost, highly accurate low capacitance measurement system that can be used over a range of 0 – 400 pF with a resolution of 1 pF. The range of capacitance may be easily altered by a simple resistance or capacitance variation of the measurement circuit. This capacitance measurement system uses quad two-input NAND Schmitt trigger circuit CD4093B ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advanced Biomedical Engineering

سال: 2023

ISSN: ['2187-5219']

DOI: https://doi.org/10.14326/abe.12.117