Development of a rechargeable optical hydrogen peroxide sensor - sensor design and biological application.

Hydrogen peroxide (H2O2) is an important member of the reactive oxygen species (ROS) family. Among ROS, H2O2 is considered the most long-lived and can accumulate inside and outside of cells, where it is involved in both vital (signaling) and deadly (toxic) reactions depending on its concentration. Quantifying H2O2 within biological samples is challenging and often not possible. Here we present ...

متن کامل

Electrochemical production of Graphene Oxide and its application as a novel Hydrogen Peroxide sensor

Herein, graphene oxide is produced by electrochemical oxidation method from graphite rod to examine its hydrogen peroxide sensing ability. The electrochemically produced graphene oxide is characterized by SEM and XRD. A few layers of Graphene Oxide(GO) sheets and corrugations in graphene sheets appeared intensely crumpled and folded into a typical wrinkled structure after electrochemical oxidat...

متن کامل

Design and Evaluation of a Novel Bismuth Optical Sensor Using PC-ANN Application

The characterization of and construction of a new optical sensor based on the immobilization of Pyrocatechol Violet on a triacetylcellulose membrane was described to for the determination of bismuth (III) in real samples. The interaction between sensing membrane and bismuth (III) was caused at pH 3.80 in acetate buffer solution and the color changed from yellow to blue along with the appearance...

متن کامل

Design and Application of a Photoacoustic Sensor for Monitoring the Laser Generated Stress Waves in Optical Fiber

Measurement of stress transients generated by a 400ns pulsed HF laser in an infrared fluoride glass fiber has been made using fast time – response piezoelectric film transducer. Acoustic signals up to 12 mV with frequencies ranging in megahertz generated by 21 mJ laser pulse when passed through the fiber axis in the linear region. It is shown that useful information such as onset of non - linea...

متن کامل

Nox4: A Hydrogen Peroxide-Generating Oxygen Sensor

Nox4 is an oddity among members of the Nox family of NADPH oxidases [seven isoenzymes that generate reactive oxygen species (ROS) from molecular oxygen] in that it is constitutively active. All other Nox enzymes except for Nox4 require upstream activators, either calcium or organizer/activator subunits (p47(phox), NOXO1/p67(phox), and NOXA1). Nox4 may also be unusual as it reportedly releases h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Analyst

سال: 2016

ISSN: 0003-2654,1364-5528

DOI: 10.1039/c6an00864j