Development of a Non-contact Ultrasonic Pollination Device
نویسندگان
چکیده
منابع مشابه
Guided Wave Non-contact Ultrasonic for Nde
Non-contact ultrasonic, enables rapid testing of structures using ultrasonic tests that are not possible via conventional contact transducers. This paper reports on laser ultrasonic and air/gas coupled ultrasonic measurements that are performed remotely, do not require direct access to test area, do not need traditional ultrasonic coupling and do not have traditional C-scan fixture requirements...
متن کاملDevelopment and Application of Contact-type Line-focus Ultrasonic Probe
A contact-type line-focus ultrasonic probe has been developed. The probe is composed of a quarter cylindrical wedge and a piezoelectric transducer attached to its cylindrical surface. A key feature of the developed probe is that longitudinal wave is incident to the testing object at all angles from 0° to 90° simultaneously. Basic characteristics of the probe have been examined by visualizing ul...
متن کاملDevelopment of an Ultrasonic Airflow Measurement Device for Ducted Air
In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of co...
متن کاملA Clinically Affordable Non-Contact Wound Measurement Device
In this paper we present a hand-held, clinically affordable, non-contact wound measurement device. The device was designed with ease of use in mind and to be capable of processing a single wound in under 1 minute. The current prototype is built on a Sony-Ericsson P900 phone and interfaces via Bluetooth with a laptop where the majority of data processing is done. The proposed final version of th...
متن کاملA new non-contact optical device for ocular biometry.
BACKGROUND A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation curre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Environment Control in Biology
سال: 2015
ISSN: 1880-554X,1883-0986
DOI: 10.2525/ecb.53.85