1 Signal Processing Methods for Doppler Radar Heart Rate Monitoring ∗
A practical means for unobtrusive and ubiquitous detection and monitoring of heart and respiration activity from a distance could be a powerful tool for health care, emergency, and surveillance applications, yet remains a largely unrealized goal. Without the need for contact or subject preparation (special clothing, attachments, etc.), this could better extend health monitoring to the chronical...
متن کاملDoppler Radar Architectures and Signal Processing for Heart Rate Extraction
In this paper heartbeat interval extraction methods using Doppler radar are reviewed. While single channel CW radar offers simple architecture and signal processing, this method is very sensitive to subject position. Quadrature radio architecture is used to overcome this limitation. The use of linear and non-linear demodulation methods was explored for heartbeat interval extraction, and it was ...
متن کاملRadar Signal Detection in K-distributed Clutter by Pade Approximation
In this paper, two suboptimum detectors are proposed for coherent radar signal detection in K-distributed clutter. Assuming certain values for several initial moments of clutter amplitude, the characteristic function of the clutter amplitude is approximated by a limited series. Using the Pade approximation, it is then converted to a rational fraction. Thus, the pdf of the clutter amplitude is o...
متن کاملDeciding Graph non-Hamiltonicity via a Closure Algorithm
We present a matching and LP based heuristic algorithm that decides graph non-Hamiltonicity. Each of the n! Hamilton cycles in a complete directed graph on n + 1 vertices corresponds with each of the n! n-permutation matrices P, such that pu,i = 1 if and only if the ith arc in a cycle enters vertex u, starting and ending at vertex n + 1. A graph instance (G) is initially coded as exclusion set ...
متن کاملMicrowave Doppler Radar for Heart Beat Detection Versus Electrocardiogram
This paper provides a validation approach for a microwave Doppler Radar system used for heartbeat detection. The proposed system is tested at 16 GHz with several transmitted power, simultaneously with a pc-based electrocardiogram. Obtained results show accurate detection for the heartbeat signal in terms of heartbeat rate and heart rate variability.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biomedical Signal Processing and Control
سال: 2021
ISSN: 1746-8094
DOI: 10.1016/j.bspc.2020.102314